PDS-30 Instruction Guide Digital Power Supply Unit for LED Lights Safety Precautions *Please read this instruction guide before using the produ
2-6 External Control External control mode may be selected by turning DIP switch # 2 (remote) ON. The position of DIP switch # 3 determines whether bi
(5) Other I/O and Voltage Levels The same ON/OFF signal (B11) and trigger signal (B12) that are input from the terminal block signals can be input fro
4. Connectors 4-1 Output connector: SM connector (mfd. by JST) Pin No. 12 V output 24 V output Output with fan (Note) 1 OUT+(+12V) OUT+(
5. PDS Side Input Circuit (Negative logic) Light intensity data: B1 – B8 Control signal: INT/EXT, WR, OFF/ON, TRIG Use with driver IC or NPN open coll
8. Dimensional diagrams 8-1 PDS-30 Light
9. RS-232C External Control 9-1 RS-232C External Control (9-pin D-sub) Turning DIP switch # 2 and # 3 ON e
R: Reset Command Name Reset command Header code R Function It resets the transmission sequence that is being executed, clears all transmission buffers
T: Trigger Output Delay Setting Command Name Trigger output delay setting command Header code T Function It sets the delay time of external output t
S: Strobe Light Width Setting Command Name Strobe Light Width Setting command Header code S Function It sets the pulse width for strobe light. @ 99
(Notes) Error Numbers Error numbers are defined as follows: 1: Faulty command error 2: Check error 3: Setting out-of-range error Notation
Danger Please read this instruction guide carefully before using the product. Following personnel should not handle this product. 1. A person who
When the luminosity of light fluctuate due to excess amount of noise, please contact CCS. General Precautions Regarding to External C
10. Glossary 1. Parallel Method which is used to send multiple data simultaneously, and its
11. RoHS Directive 11-1 EU RoHS Directive The RoHS Directive is short for the "restrict
11-2 China RoHS Directive China RoHS Directive is formally known as "Management Methods for Controlling Pollution by Electronic Infor
12. Warranty Information Warranty period: Two years (one year for radiant quantity), starting from CCS
Please use electricity within the product specification (PDS-30:AC100-240V, 50/60Hz). Otherwise, it may cause fire or electric shock. Please avoid
Always provide a dedicated electric power source with stable voltage. Sharing the electric power source with other power devices, such as inverters, m
Contents 1. Features 2. Specifications 2-1 Specifications 2-2 Voltage Selector 2-3 Contin
1. Features 1-1 This product is a digital power supply for controlling CCS LED lights. 1-2 Selectable 12V DC and 24V DC output (cannot be us
2. Specifications 2-1 Specifications ModelPDS-30Input voltage 100 to 240V AC Input power 46W 110VA max. (at
The product can be used as a conventional 12-V DC or 24-V DC power supply. Continuous and strobe light options are available in either voltage. 2-2
2-4 Strobe Light Refer to other sections for the settings at # 2, # 3, # 4, and 6. Dip switch # 5 is not used in strobe light. Light pulse wi